RC Snubber Calculator (Ringing Frequency Method)

Santaji Gadepatil
B.E. (Electronics & Telecommunication) · Founder & Editor
Connect on LinkedIn
Share
Published
Last updated
Read time
5 min
RC Snubber Calculator (Ringing Frequency Method): formula and free online calculator

Fast switching edges in MOSFET, diode and transformer circuits excite the stray inductance and capacitance of the layout into high-frequency ringing that raises voltage stress and EMI. This RC snubber calculator uses the proven measure-and-add-capacitance method: from the ringing frequency before and after adding a known test capacitor it finds the parasitic capacitance and inductance, the characteristic impedance, and a resistor and capacitor that damp the ringing — plus the power the snubber resistor must dissipate. The design steps follow this guide to RC snubber circuit design.

calculated
calculated
calculated
calculated
calculated
calculated
calculated
Type in any field to change it. Press × on a value to calculate that field instead.

How to use the RC snubber calculator

Measure the ringing frequency at the switch node with the circuit running and a short ground lead on the scope probe. Solder a test capacitor across the device (start with a few hundred pF) and measure the new ringing frequency — aim for about half the original. Enter both frequencies and the test capacitor, the capacitor multiplier, the voltage switched and the switching frequency. The calculator gives the parasitic capacitance and inductance, the characteristic impedance, the snubber resistor and capacitor and the resistor’s power dissipation.

RC snubber formulas

Cp = Cadd ÷ [(f0 ÷ f1)² − 1]  ·  Lp = 1 ÷ [(2π f0)² Cp]

Rs = Z0 = √(Lp ÷ Cp)  ·  Cs = k × Cp (k ≈ 3–4)  ·  PR = Cs V² fsw

The ringing is the resonance of the loop inductance with the parasitic capacitance, f = 1 ÷ (2π√(LC)). A resistor equal to the characteristic impedance gives close to critical damping; the series capacitor blocks DC so the resistor only conducts during the edges.

Worked example

A 48 V synchronous buck switching at 200 kHz rings at 80 MHz on the switch node. Adding 220 pF across the low-side MOSFET drops the ringing to 40 MHz:

  • Frequency ratio squared (f0 ÷ f1)² = (80 ÷ 40)² = 4
  • Parasitic capacitance Cp = 220 ÷ (4 − 1) = 73.33 pF
  • Parasitic inductance Lp = 1 ÷ ((2π × 80 MHz)² × 73.33 pF) = 53.97 nH
  • Snubber resistor Rs = √(53.97 nH ÷ 73.33 pF) = 27.13 Ω — use 27 Ω
  • Snubber capacitor Cs = 4 × 73.33 = 293.3 pF — use 330 pF (or 270 pF)
  • Resistor power P = 293.3 pF × 48² × 200 kHz = 0.135 W; time constant RsCs = 7.96 ns

Parasitic capacitance from the frequency drop

f0 ÷ f1 Cp Cadd = 100 pF 220 pF 470 pF 1 nF
1.2 2.273 × Cadd 227 pF 500 pF 1068 pF 2273 pF
1.5 0.800 × Cadd 80 pF 176 pF 376 pF 800 pF
2 0.333 × Cadd 33 pF 73 pF 157 pF 333 pF
2.5 0.190 × Cadd 19 pF 42 pF 90 pF 190 pF
3 0.125 × Cadd 12 pF 28 pF 59 pF 125 pF

Snubber resistor power P = C V² f

Voltage 100 pF at 100 kHz 470 pF at 100 kHz 1 nF at 100 kHz 1 nF at 500 kHz 4.7 nF at 100 kHz
12 V 1.4 mW 6.8 mW 14.4 mW 72.0 mW 67.7 mW
24 V 5.8 mW 27.1 mW 57.6 mW 288.0 mW 270.7 mW
48 V 23.0 mW 108.3 mW 230.4 mW 1.15 W 1.08 W
100 V 100.0 mW 470.0 mW 1.00 W 5.00 W 4.70 W
400 V 1.60 W 7.52 W 16.00 W 80.00 W 75.20 W

Practical notes

  • Fix the layout first: a shorter hot loop and a closer input capacitor reduce Lp, raise the ringing frequency and reduce the energy the snubber has to absorb.
  • Check the result: fit the calculated R and C, then confirm on the scope that the overshoot is damped within one or two cycles. Adjust R ±50% to fine-tune; if the loss is too high, reduce k towards 2.
  • Rating: the resistor sees pulses of up to V ÷ R at every edge — choose a pulse-rated part and allow at least twice the calculated average power.
  • Snubber loss counts as switching loss — include it in the converter efficiency with the MOSFET power loss calculator. To check the ringing frequency from L and C, use the resonant frequency calculator.

Frequently asked questions

How do you calculate an RC snubber?

Measure the ringing frequency f₀, add a known capacitor C_add across the switch and measure the new frequency f₁. The parasitic capacitance is C_p = C_add ÷ ((f₀ ÷ f₁)² − 1), the inductance L_p = 1 ÷ ((2πf₀)² C_p) and the snubber resistor R = √(L_p ÷ C_p). Choose the snubber capacitor 3–4 times C_p so that R, not the capacitor, sets the damping.

How much power does a snubber resistor dissipate?

P = C_s × V² × f_sw — the capacitor's stored energy ½C V² is dissipated in the resistor once when it charges and once when it discharges, every switching cycle. A 293 pF snubber switching 48 V at 200 kHz dissipates about 0.13 W, so a 0.25 W or larger pulse-rated resistor is used.

Why add a capacitor until the frequency halves?

When f₁ = f₀ ÷ 2 the added capacitor is exactly three times the parasitic capacitance, so the measurement is well above the scope probe and fixture capacitance and the result is not sensitive to small reading errors. Any ratio works with the formula, but ratios close to 1 give poor accuracy.

What type of resistor and capacitor should a snubber use?

Use a low-inductance resistor (thick-film or carbon composition, not wirewound) and a capacitor with low ESL rated well above the peak voltage — C0G/NP0 ceramic or polypropylene film. Keep the snubber loop as short as possible, directly across the device that rings.

Free widget

Put this calculator on your website

Copy one snippet. It resizes itself and works on any site or blog.

<iframe src="https://zentacalculator.com/embed/electronics/rc-snubber/" title="RC Snubber Calculator (Ringing Frequency Method)" width="100%" height="640" style="border:1px solid #e2e5ee;border-radius:12px;max-width:720px" loading="lazy"></iframe>
<p style="font-size:13px"><a href="https://zentacalculator.com/electronics/rc-snubber/">RC Snubber Calculator (Ringing Frequency Method)</a> by <a href="https://zentacalculator.com/">Zenta Calculator</a></p>
<script>addEventListener('message',function(e){if(e.origin==='https://zentacalculator.com'&&e.data&&e.data.zentaHeight){document.querySelectorAll('iframe[src="https://zentacalculator.com/embed/electronics/rc-snubber/"]').forEach(function(f){if(f.contentWindow===e.source)f.style.height=e.data.zentaHeight+'px'})}})</script>
Why Zenta Calculator

From formula to answer in seconds

One clear path from the numbers you have to a result you can use, for students, engineers and everyday users.

  1. 01

    Enter what you know

    Type any values you have, in the units you use. Leave the unknown blank and the calculator solves for it.

  2. 02

    See the formula and steps

    Every result shows the equation, a worked example and a chart, so you understand the answer and not just the number.

  3. 03

    Get answers you can trust

    Formulas follow published standards and textbooks, and every worked example is checked before a page goes live.