Tank Drain Time Calculator (Fill & Empty Time): formula and free online calculator

A tank emptying through a bottom outlet slows down as it drains, because the outflow velocity follows the square root of the liquid head. This tank drain time calculator applies Torricelli's law to give the time between two levels, the start and end outflow, and the time to refill at a set flow.

Process and maintenance engineers use it to plan tank cleaning and batch transfers, and to choose an outlet size that empties a vessel within the time available.

calculated
calculated
calculated
calculated
calculated
calculated
Type in any field to change it. Press × on a value to calculate that field instead.

How to use the tank drain time calculator

Enter the inside diameter of the vertical tank, the diameter of the outlet and its type (which sets the discharge coefficient), and the starting and final levels measured above the outlet. The calculator gives the drain time, the outflow at the start and the end, the volume drained and the average flow. Enter a fill flow rate to see how long it takes to fill the same volume back up with the outlet closed. To find the outlet size for a required drain time, enter the time and press × on the outlet diameter.

Tank drain time formula (Torricelli’s law)

Q = Cd a √(2 g h)  ·  t = (A ÷ Cd a) × √(2 ÷ g) × (√h1 − √h2)

Fill time = A (h1 − h2) ÷ Qfill

A = π D² ÷ 4 is the tank cross-section, a = π d² ÷ 4 the outlet area and g = 9.80665 m/s². The formula assumes a constant cross-section, a tank open to the atmosphere (or vented) and an outlet discharging freely to atmosphere.

Worked example

A 2 m diameter tank with a 50 mm sharp-edged bottom outlet (Cd = 0.61) drains from 3 m to 0.2 m:

  • Tank area A = π × 2² ÷ 4 = 3.1416 m²; outlet area a = π × 0.05² ÷ 4 = 19.635 cm²
  • Drain time = (3.1416 ÷ (0.61 × 0.0019635)) × √(2 ÷ 9.80665) × (√3 − √0.2) = 1,522 s = 25.37 min
  • Outflow at the start = 0.61 × 0.0019635 × √(2 × 9.80665 × 3) × 3600 = 33.07 m³/h, falling to 8.54 m³/h at 0.2 m
  • Volume drained = 3.1416 × (3 − 0.2) = 8,796 L, an average of 20.81 m³/h
  • Filling it back at 10 m³/h takes 8.7965 ÷ 10 = 52.78 min

Level against time for the example tank

Time from 3 m to each level, and the outflow at that level (50 mm sharp-edged outlet):

Level Time from 3 m Outflow
3 m 0.0 min 33.07 m³/h
2.5 m 3.0 min 30.19 m³/h
2 m 6.3 min 27.01 m³/h
1.5 m 10.0 min 23.39 m³/h
1 m 14.5 min 19.10 m³/h
0.5 m 20.2 min 13.50 m³/h
0.2 m 25.4 min 8.54 m³/h
0 m 34.2 min 0.00 m³/h

Emptying completely takes 34.2 min — the last 0.2 m alone takes 8.8 min.

Time to empty a tank from 3 m

Sharp-edged outlet (Cd = 0.61), starting 3 m above the outlet:

Tank diameter 25 mm outlet 50 mm outlet 100 mm outlet 150 mm outlet
1 m 34.2 min 8.5 min 2.1 min 0.9 min
2 m 136.8 min 34.2 min 8.5 min 3.8 min
3 m 307.7 min 76.9 min 19.2 min 8.5 min
5 m 854.9 min 213.7 min 53.4 min 23.7 min

Doubling the outlet diameter cuts the time by four; doubling the tank diameter multiplies it by four.

Practical notes

  • Drain lines and valves: if the tank empties through a pipe, the friction and fittings reduce the flow. Use the orifice flow calculator or a pipe pressure-drop calculation for the real outflow; a pipe that drops below the tank adds head and can speed up draining.
  • Closed tanks need a vent sized for the outflow, otherwise the vacuum above the liquid slows or stops draining.
  • Cone or dished bottoms hold extra liquid below the straight side; for a cone bottom tank the last part drains faster than this formula predicts because the area shrinks.
  • Vortexing near the end of draining can draw air into the outlet and reduce the flow further.

Outlet type and drain time

The discharge coefficient changes the time in direct proportion. For the default 2 m tank and 50 mm outlet:

Outlet Cd 3 m to 0.2 m 3 m to empty
Re-entrant tube 0.50 30.9 min 41.7 min
Sharp-edged hole 0.61 25.4 min 34.2 min
Short nozzle 0.82 18.9 min 25.4 min
Bell-mouth 0.97 16.0 min 21.5 min

Swapping a sharp-edged hole for a short nozzle of the same bore cuts the drain time from 25.4 to 18.9 minutes without any change to the tank.

Sizing an outlet for a target time

Drain time is inversely proportional to the outlet area, so the bore scales with the square root of the time ratio. To bring the default tank from 3 m to 0.2 m in 15 minutes instead of 25.37, the outlet must be 50 × √(25.37 ÷ 15) = 65.0 mm, so a standard DN65 nozzle does the job.

Checking the outlet on site

Timing a real drain is a quick check of the outlet. If the default tank takes 30 minutes instead of the calculated 25.37, the effective coefficient is 0.61 × 25.37 ÷ 30 = 0.516. A value well below the table suggests a partly closed valve, a strainer, debris in the nozzle or a drain line long enough for friction to control the flow. Level can be read from a sight glass, a dip tape or the level transmitter trend, using two readings well apart so the timing error stays small.

Common mistakes

  • Assuming the flow stays at its starting value. Dividing the volume by the initial outflow gives 8.80 m³ ÷ 33.07 m³/h × 60 = 16.0 min, far short of the real 25.4 min.
  • Measuring levels from the tank floor. The head is measured from the outlet centre; for a side nozzle 300 mm above the floor, the liquid below the nozzle never drains and the levels entered must be reduced by 0.3 m.
  • Using Cd 0.61 for a drain line. Once the liquid passes through a pipe, valve and bends, friction controls the flow and the effective coefficient may be 0.2 to 0.4.
  • Applying water figures to viscous liquids. Oils, syrups and slurries have lower coefficients, especially at low head near the end of draining.
  • Leaving an inflow running. Any feed still entering the tank extends the drain time, and if it exceeds the outflow at the final head, the level never reaches it.

Frequently asked questions

How do you calculate the time to drain a tank?

For a vertical cylindrical tank open to the atmosphere and emptying through a bottom outlet, Torricelli's law gives the outflow Q = C_d a √(2 g h). Integrating as the level falls gives t = (A ÷ (C_d a)) × √(2 ÷ g) × (√h₁ − √h₂), where A is the tank cross-section and a the outlet area.

Why does a tank drain more slowly as it empties?

The outflow velocity is √(2 g h), so it falls as the head h drops. Draining the bottom quarter of the height takes as long as draining the top three quarters, and emptying a tank from full takes twice as long as it would at the starting flow rate.

What discharge coefficient should I use?

About 0.61 for a sharp-edged hole in a thin plate, 0.8–0.82 for a short tube or nozzle, 0.95–0.98 for a smooth bell-mouthed outlet and about 0.5 for a tube projecting into the tank. If the tank drains through a long pipe or a valve, the pipe friction controls the flow and the coefficient is much lower.

How is the fill time calculated?

With a constant inflow and the outlet closed, the fill time is simply the volume between the two levels divided by the flow rate. If the outlet stays open, the level rises only until the outflow √(2 g h) term equals the inflow.

Can I use this for viscous liquids like oil or syrup?

Only as a first estimate. Viscous liquids discharge with a lower coefficient, and it drops further as the head falls, so the real time is longer. Time a test drain and back-calculate the coefficient for the liquid you handle.

How can I check the discharge coefficient of my tank outlet?

Time the level fall between two marks and scale the coefficient by calculated time over measured time. If the default tank takes 30 minutes instead of 25.4, the effective coefficient is about 0.52.

Free widget

Put this calculator on your website

Copy one snippet. It resizes itself and works on any site or blog.

<iframe src="https://zentacalculator.com/embed/engineering/tank-drain-time/" title="Tank Drain Time Calculator (Fill & Empty Time)" width="100%" height="640" style="border:1px solid #e2e5ee;border-radius:12px;max-width:720px" loading="lazy"></iframe>
<p style="font-size:13px"><a href="https://zentacalculator.com/engineering/tank-drain-time/">Tank Drain Time Calculator (Fill & Empty Time)</a> by <a href="https://zentacalculator.com/">Zenta Calculator</a></p>
<script>addEventListener('message',function(e){if(e.origin==='https://zentacalculator.com'&&e.data&&e.data.zentaHeight){document.querySelectorAll('iframe[src="https://zentacalculator.com/embed/engineering/tank-drain-time/"]').forEach(function(f){if(f.contentWindow===e.source)f.style.height=e.data.zentaHeight+'px'})}})</script>
Why Zenta Calculator

From formula to answer in seconds

One clear path from the numbers you have to a result you can use, for students, engineers and everyday users.

  1. 01

    Enter what you know

    Type any values you have, in the units you use. Leave the unknown blank and the calculator solves for it.

  2. 02

    See the formula and steps

    Every result shows the equation, a worked example and a chart, so you understand the answer and not just the number.

  3. 03

    Get answers you can trust

    Formulas follow published standards and textbooks, and every worked example is checked before a page goes live.