Cone Bottom Tank Volume Calculator (Level to Volume)

Many process tanks, silos and hoppers have a conical bottom so they drain fully, which makes level and volume non-linear near the outlet. This cone bottom tank volume calculator gives the liquid volume for any level from the outlet, plus total capacity, percent full, cone volume and cone angle.
Instrument and process engineers use it to build strapping tables for automatic tank gauging or a level transmitter, and operators use it to check stock and batch quantities.
How to use the cone bottom tank volume calculator
Enter the inside diameter of the tank, the height of the straight cylindrical side, the height of the cone and the outlet diameter at the bottom of the cone (0 for a pointed cone). Then enter the liquid level measured from the outlet. The calculator gives the liquid volume, the total capacity, the percentage full, the volume of the cone section, the diameter of the liquid surface and the cone angle. To find the level for a given volume, enter the volume and press × on the level.
Cone bottom tank volume formulas
Vcone = π hc (d² + d D + D²) ÷ 12 · Vtotal = Vcone + π D² H ÷ 4
Level h ≤ hc: Ds = d + (D − d) h ÷ hc, V = π h (d² + d Ds + Ds²) ÷ 12
Level h > hc: V = Vcone + π D² (h − hc) ÷ 4 · included angle = 2 atan[(D − d) ÷ (2 hc)]
Worked example
A tank 2 m in diameter with a 3 m straight side, a 1 m deep cone and a 100 mm outlet, filled to 2.5 m above the outlet:
- Cone volume = π × 1 × (0.1² + 0.1 × 2 + 2²) ÷ 12 = 1,102.2 L
- Total capacity = 1,102.2 + π × 2² × 3 ÷ 4 × 1000 = 10,527.0 L
- The level is above the cone, so the liquid surface is the full 2 m diameter
- Liquid volume = 1,102.2 + π × 2² × (2.5 − 1) ÷ 4 × 1000 = 5,814.6 L
- Percent full = 5,814.6 ÷ 10,527.0 = 55.24%
- Included cone angle = 2 atan(1.9 ÷ 2) = 87.06°, so the walls slope at 46.47° from horizontal
Level to volume table for the example tank
| Level from outlet | Surface diameter | Volume | Percent full |
|---|---|---|---|
| 0.25 m | 0.575 m | 26 L | 0.2% |
| 0.5 m | 1.050 m | 159 L | 1.5% |
| 0.75 m | 1.525 m | 489 L | 4.6% |
| 1 m | 2.000 m | 1,102 L | 10.5% |
| 1.5 m | 2.000 m | 2,673 L | 25.4% |
| 2 m | 2.000 m | 4,244 L | 40.3% |
| 2.5 m | 2.000 m | 5,815 L | 55.2% |
| 3 m | 2.000 m | 7,385 L | 70.2% |
| 3.5 m | 2.000 m | 8,956 L | 85.1% |
| 4 m | 2.000 m | 10,527 L | 100.0% |
The first quarter of the cone height holds very little liquid — which is why level transmitters on cone bottom tanks need a strapping table rather than a linear scale.
Cone height and volume for common cone angles
Pointed cones (outlet diameter 0); each cell gives the cone height and the volume it holds.
| Tank diameter | 60° included angle | 90° included angle | 120° included angle |
|---|---|---|---|
| 1 m | 0.866 m / 227 L | 0.500 m / 131 L | 0.289 m / 76 L |
| 1.5 m | 1.299 m / 765 L | 0.750 m / 442 L | 0.433 m / 255 L |
| 2 m | 1.732 m / 1,814 L | 1.000 m / 1,047 L | 0.577 m / 605 L |
| 3 m | 2.598 m / 6,122 L | 1.500 m / 3,534 L | 0.866 m / 2,041 L |
| 4 m | 3.464 m / 14,510 L | 2.000 m / 8,378 L | 1.155 m / 4,837 L |
Practical notes
- Measure the level from the true bottom: a level transmitter mounted on the cone or the straight side has a zero offset — add the height of its tapping above the outlet before using this calculator.
- Dead volume: liquid in the outlet nozzle and pipe below the cone is not included.
- For a flat-bottomed vertical tank use the vertical tank volume calculator; for a horizontal drum use the horizontal tank volume calculator.
- Solids: for powders in a silo, the top surface forms a heap at the angle of repose instead of a flat surface, and the bulk density varies with compaction, so treat the result as an estimate.
From a transmitter reading to volume and mass
A level transmitter rarely sits at the outlet. On the default tank, a DP transmitter used for level measurement has its lower tapping 150 mm above the outlet and reads 1.2 m:
- Level from the outlet = 0.15 + 1.2 = 1.35 m, above the 1 m cone
- Volume = 1,102.2 + π × 2² × (1.35 − 1) ÷ 4 × 1000 = 2,201.7 L
- For a liquid with relative density 1.1, the stock is 2,422 kg
Entering the raw 1.2 m reading would give only 1,730.5 L, an error of 471 L that comes from the offset in the cone alone. On a DP transmitter the reading also depends on the density set in the transmitter, so a change of product needs a new range as well as a new table.
Checking the table by water strapping
For custody or batching duties the calculated table is confirmed by filling the empty tank with water through a calibrated flow meter in steps, recording the level at each step. The calculated and measured figures usually differ in the cone, where dished welds, a sloping outlet nozzle or an internal agitator foot take up volume. The measured table then replaces the calculated one in the gauging system.
Common mistakes
- Using the slant height of the cone. The formula needs the vertical height. Entering the 1.379 m slant length of the default cone would give a cone volume of 1,520 L instead of 1,102 L.
- Ignoring the outlet diameter. Treating the 100 mm outlet as a point with the same 1 m cone height gives 1,047 L in the cone, 55 L too little.
- Using the outside diameter. Drawings often give the shell OD; subtract twice the wall thickness, since 6 mm of wall on a 2 m tank changes the volume by about 1.2%.
- Reading percent level as percent volume. At 0.5 m the tank is 12.5% of its height but holds only 1.5% of its capacity.
- Forgetting the transmitter offset. Add the height of the lower tapping or sensor above the outlet before entering the level, as in the example above.
Frequently asked questions
How do you calculate the volume of a cone bottom tank?
Add the volume of the cone (a frustum if the outlet has a diameter) to the volume of the cylinder above it. The cone holds V = π h (d² + d D + D²) ÷ 12, where h is the cone height, D the tank diameter and d the outlet diameter; the cylinder holds π D² H ÷ 4. For d = 0 the cone formula becomes π D² h ÷ 12, one third of a cylinder of the same height.
How do you find the volume at a level inside the cone?
The liquid forms a smaller cone (or frustum). Its surface diameter grows linearly from the outlet diameter at the bottom to the tank diameter at the top of the cone, so at level h it is d + (D − d) h ÷ h_cone, and the volume is π h (d² + d Dₛ + Dₛ²) ÷ 12.
Why is the volume not proportional to the level in a cone bottom tank?
In the cone the cross-section grows with the square of the height, so the first 10% of the cone height holds only about 0.1% of the cone volume for a pointed cone. Above the cone the tank is a straight cylinder and every metre of level adds the same volume.
What cone angle should a hopper or tank bottom have?
Liquid tanks often use a 60°–90° included angle (walls 45°–60° from horizontal). Hoppers for powders and granular solids usually need steeper walls, often 60°–70° from horizontal, for reliable mass flow — the exact angle depends on the wall friction of the material.
How do I convert the tank volume to mass?
Multiply the volume by the liquid density. 2,202 L of a liquid with relative density 1.1 is about 2,422 kg. Use the density at the actual temperature, since many liquids change by 0.1% or more per 10 °C.
Should I use the slant height or the vertical height of the cone?
The vertical height, measured from the outlet to the joint with the straight side. The slant length is always longer; on the default tank it is 1.379 m against 1 m and would overstate the cone volume.
Related calculators
- EngineeringVertical Tank Volume CalculatorCalculate the volume of liquid in a vertical cylindrical tank from its diameter and level, with full capacity, percentage fill and litres per mm.Open calculator
- EngineeringHorizontal Tank Volume CalculatorCalculate liquid volume in a partially filled horizontal cylindrical tank from its level, and the level for a given volume.Open calculator
- MathFrustum Volume CalculatorCalculate the volume, slant height, lateral area and total surface area of a conical frustum (truncated cone) from the two radii and height.Open calculator
- EngineeringTank Drain Time CalculatorCalculate how long a tank takes to drain by gravity through a bottom outlet (Torricelli's law), the outflow rate, and the time to fill it at a set flow.Open calculator
- MathCone CalculatorCalculate a cone's volume, slant height and surface area from its radius and height.Open calculator
- EngineeringAir Receiver Size CalculatorCalculate compressed air receiver tank size for a peak demand event and for compressor load/unload cycling, from flow, pressure band and time.Open calculator