Liquid Thermal Expansion Calculator (Volumetric)

Liquids expand far more than solids when heated, which is why fuel tanks, hot-water systems and closed pipelines need expansion space or thermal relief valves. This liquid thermal expansion calculator applies ΔV = β V₀ ΔT to find the volume change, the final volume and the percentage increase.

calculated
calculated
calculated
Type in any field to change it. Press × on a value to calculate that field instead.

How to use the liquid thermal expansion calculator

Enter the liquid’s volumetric expansion coefficient β in units of 10⁻⁶ per kelvin, the initial volume and the initial and final temperatures. The calculator returns the volume increase, the final volume and the percentage change. A negative result means the liquid contracts on cooling.

Volumetric expansion formula

ΔV = β × V0 × (T2 − T1)  ·  V1 = V0 + ΔV

Example

A tank is filled with 1,000 L of petrol at 15 °C, which then warms to 35 °C in the sun (β = 950 × 10⁻⁶/K):

  • ΔT = 35 − 15 = 20 K
  • ΔV = 950 × 10⁻⁶ × 1000 × 20 = 19.0 L
  • Final volume = 1,019 L, an increase of 1.9%

Expansion coefficients and volume change per 1,000 L

Liquid β (×10⁻⁶/K, near 20 °C) ΔT = 10 K ΔT = 20 K ΔT = 40 K
Water (at 20 °C) 207 2.07 L 4.14 L 8.28 L
Mercury 181 1.81 L 3.62 L 7.24 L
Glycerine 505 5.05 L 10.10 L 20.20 L
Petrol (gasoline) 950 9.50 L 19.00 L 38.00 L
Kerosene / jet fuel 990 9.90 L 19.80 L 39.60 L
Ethanol 1090 10.90 L 21.80 L 43.60 L
Acetone 1430 14.30 L 28.60 L 57.20 L

Coefficients are typical values near room temperature; they vary with temperature and composition.

Why it matters

  • Blocked-in liquid: a full, closed pipe that warms up builds pressure very quickly because liquids are nearly incompressible — fit a thermal relief valve.
  • Tank ullage: leave enough free space for the expansion over the full storage temperature range.
  • Custody transfer: fuel volumes are corrected to 15 °C (or 60 °F) using expansion tables.
  • For solids (pipes, rails), use the linear thermal expansion calculator.

Frequently asked questions

What is the formula for thermal expansion of a liquid?

ΔV = β × V₀ × ΔT, where β is the volumetric expansion coefficient (per K), V₀ the initial volume and ΔT the temperature rise. The final volume is V₀ (1 + β ΔT).

How much does petrol expand when it warms up?

About 0.095% per °C. 1,000 L delivered at 15 °C becomes about 1,019 L at 35 °C, which is why fuel is traded at a reference temperature of 15 °C.

Why does water expand differently?

Water's β changes strongly with temperature — it is zero at 4 °C (maximum density), about 207 × 10⁻⁶/K at 20 °C and about 750 × 10⁻⁶/K near 100 °C. For large temperature changes use densities from a steam table instead of a single β.

Does the container expansion matter?

Yes. A steel tank's volume grows by about 3α ≈ 36 × 10⁻⁶ per K, so the apparent expansion of the liquid is β − 3α. For most liquids this is a small correction.

Embed this calculator

Free to use on your website or blog. Copy this code: